    Suitable for overhead power lines with rated AC voltages of 35 kV and below, and intended for use in locations with high safety requirements, such as urban areas, high-rise buildings, and forested regions.

    Usage characteristics

    Rated voltage The rated voltage is 1.10 kV.

    Operating temperature The insulation made of polyvinyl chloride or polyethylene should not exceed 70℃, while cross-linked polyethylene insulation should not exceed 90℃. During a short circuit, the duration should not exceed 5 seconds.

    Temperature of the cable conductor The insulation made of polyvinyl chloride should not exceed 160℃; the insulation made of polyethylene should not exceed 150℃; and the insulation made of cross-linked polyethylene should not exceed 250℃. The installation temperature for cables should not be lower than -20℃.

     Aluminum-core overhead line

  • Aluminum-core overhead line
Aluminum-core overhead line
+

Aluminum-core overhead line

Suitable for overhead power lines with rated AC voltages of 35 kV and below, and intended for use in locations with high safety requirements, such as urban areas, high-rise buildings, and forested regions.

If you need customized products,Contact us!

Share to

  • Product Description
  • Product Description

    Suitable for overhead power lines with rated AC voltages of 35 kV and below, and intended for use in locations with high safety requirements, such as urban areas, high-rise buildings, and forested regions.

    Usage characteristics

    Rated voltage The rated voltage is 1.10 kV.

    Operating temperature The insulation made of polyvinyl chloride or polyethylene should not exceed 70℃, while cross-linked polyethylene insulation should not exceed 90℃. During a short circuit, the duration should not exceed 5 seconds.

    Temperature of the cable conductor The insulation made of polyvinyl chloride should not exceed 160℃; the insulation made of polyethylene should not exceed 150℃; and the insulation made of cross-linked polyethylene should not exceed 250℃. The installation temperature for cables should not be lower than -20℃.