Product Description
-
Product Description
-
Power cables are used for transmitting and distributing electrical energy. They are commonly employed in urban underground power grids, outgoing lines from power plants, and internal power supply systems within industrial and mining enterprises. In the main transmission lines of power systems, power cables serve to transmit and distribute high-power electricity; these include cables of various voltage levels—ranging from 1 kV to 500 kV and above—with different types of insulation.
I. Product Name / Rated Voltage
(0.6/1kV): Cross-linked polyethylene insulated power cable
Main raw materials: copper and aluminum conductors, cross-linked polyethylene (XLPE) insulation, PVC sheath
II. Product Implementation Standards
The cable design complies with the requirements of the national standard GB/T 12706-2008 and the International Electrotechnical Commission’s recommended standard IEC 60502.
III. Product Applications
The normal operating temperature of the conductor in cross-linked polyethylene insulated cables is 90°C. Cross-linked polyethylene cables not only exhibit excellent electrical performance, with high operating temperatures and large transmission capacities, but also offer advantages such as simple construction, small outer diameter, light weight, ease of installation and use, and no restrictions on laying elevation differences. They are widely used in industrial and mining enterprises and urban power grids.
IV. Scope of Application
Scope of application for power cables: They are suitable for installation indoors, outdoors, in ducts, cable trenches, and in loose soil. They can withstand a certain amount of pulling during installation but cannot endure external mechanical forces. Single-core cables must not be installed in magnetic conduits.
V. Product Usage Characteristics
1. The ambient temperature during installation shall not be lower than 0°C (if below 0°C, preheating is required), and there are no restrictions on the cable’s vertical drop.
2. The minimum bending radius during installation is specified as follows: unarmored single-core cable: 20D; unarmored three-core cable: 15D; armored single-core cable: 15D; armored three-core cable: 12D; (where D is the actual outer diameter of the cable).
3. Cable operating temperature: PVC sheath not exceeding 90°C;
4. Overload temperature: The overload temperature shall not exceed 130°C during a cable short circuit;
5. The rated temperature of the cable conductor shall not exceed 90°C, and the conductor temperature during a short circuit (not exceeding 5 seconds) shall not exceed 250°C.
High-voltage power cable
If you need a customized product,Contact us!
Product Category
Tag List
- Product Description
-
Power cables are used for transmitting and distributing electrical energy. They are commonly employed in urban underground power grids, outgoing lines from power plants, and internal power supply systems within industrial and mining enterprises. In the main transmission lines of power systems, power cables serve to transmit and distribute high-power electricity; these include cables of various voltage levels—ranging from 1 kV to 500 kV and above—with different types of insulation.
I. Product Name / Rated Voltage
(0.6/1kV): Cross-linked polyethylene insulated power cable
Main raw materials: copper and aluminum conductors, cross-linked polyethylene (XLPE) insulation, PVC sheath
II. Product Implementation Standards
The cable design complies with the requirements of the national standard GB/T 12706-2008 and the International Electrotechnical Commission’s recommended standard IEC 60502.
III. Product Applications
The normal operating temperature of the conductor in cross-linked polyethylene insulated cables is 90°C. Cross-linked polyethylene cables not only exhibit excellent electrical performance, with high operating temperatures and large transmission capacities, but also offer advantages such as simple construction, small outer diameter, light weight, ease of installation and use, and no restrictions on laying elevation differences. They are widely used in industrial and mining enterprises and urban power grids.
IV. Scope of Application
Scope of application for power cables: They are suitable for installation indoors, outdoors, in ducts, cable trenches, and in loose soil. They can withstand a certain amount of pulling during installation but cannot endure external mechanical forces. Single-core cables must not be installed in magnetic conduits.
V. Product Usage Characteristics
1. The ambient temperature during installation shall not be lower than 0°C (if below 0°C, preheating is required), and there are no restrictions on the cable’s vertical drop.
2. The minimum bending radius during installation is specified as follows: unarmored single-core cable: 20D; unarmored three-core cable: 15D; armored single-core cable: 15D; armored three-core cable: 12D; (where D is the actual outer diameter of the cable).
3. Cable operating temperature: PVC sheath not exceeding 90°C;
4. Overload temperature: The overload temperature shall not exceed 130°C during a cable short circuit;
5. The rated temperature of the cable conductor shall not exceed 90°C, and the conductor temperature during a short circuit (not exceeding 5 seconds) shall not exceed 250°C.