Inspection and Test Report-2


Inspection and Test Report-2
Serial number Major category Test Items Unit Technical Requirements Test Results Single-item judgment
1 Structural dimensions Color of the insulated wire core under test — — Red, yellow, green —
Structural dimensions Conductor material — Copper √ Qualified
Structural dimensions Number of conductors in a single wire root At least 53 60, 60, 60 Qualified
Structural dimensions Average Insulation Thickness mm — 4.4, 4.6, 4.5 —
Structural dimensions Minimum Insulation Thickness mm Minimum 3.95 4.17, 4.42, 4.31 Qualified
Structural dimensions Insulation eccentricity — Maximum 0.15 0.07, 0.07, 0.07 Qualified
Structural dimensions Average sheath thickness mm — 4.4 —
Structural dimensions Sheath minimum thickness mm Minimum 2.92 3.8 Qualified
Structural dimensions Thickness at the thinnest point of the isolation sleeve mm Minimum 1.48 2.61 Qualified
Structural dimensions Copper Tape Shielding Coverage Rate % Minimum 5 16, 17, 17 Qualified
Structural dimensions Copper strip thickness mm Minimum 0.09 0.10, 0.10, 0.10 Qualified
Structural dimensions Steel Strip Dimensions – Number of Layers × Thickness mm Minimum 2×0.72 2×0.80 Qualified
Structural dimensions Steel Belt Dimensions – Strap Clearance / Steel Belt Width % Up to 50 49 Qualified
2 Logo Logo Content Check — There shall be a continuous marking indicating the manufacturer’s name, product model, and rated voltage, and the marking shall be legible. √ Qualified
Logo Distance between signs mm Up to 500 300 Qualified
Logo Abrasion resistance of printed logos — Using a water-soaked cotton ball or cotton cloth, gently wipe the surface 10 times, then visually inspect it; the marking should remain essentially unchanged. √ Qualified